Process Data Analyzer - Change log |
| Version | Released | # | Type | Description |
|---|---|---|---|---|
| 2.0.0 | 22.09.2026 | 18256 | Change Request | Auto fit after acqusition. |
| 17384 | Change Request | Signal timing is stored per card. The unit of time has been changed to microseconds. |
||
| 15760 | Change Request | Change the configuration to be card related. The new feature saves the configuration for each card. Trace files save the configuration on a special card with ConnectionID = “TRACE_FILE_DUMMY_DEVICE”. |
||
| 18444 | New Feature | Separate UI from data acquisition. By default it runs as a client of the RAYLASE.PDA.Service and gets its data over the API. | ||
| 18397 | New Feature | Displays the unsupported signals, depending on the firmware version. | ||
| 18285 | New Feature | New Timeplot Zooming mode left aligned. Use SHIFT + Scoll to activate that mode. | ||
| 18277 | New Feature | With Mulitsegment trigger the trace file can split to an individual file per segment. | ||
| 18257 | New Feature | Enhancement of the “PDA Support File”. All open trace files and loaded overlays are now added to the support file. |
||
| 18213 | New Feature | new virtual signals (ZeroPhasePT2, MovingAverage, Count, InRange). - ZeroPhasePT2: Zero-phase second-order digital filter. |
||
| 18129 | New Feature | New keyboard shortcuts for timeplot (Pos1, End, PageUp and PageDown). new keyboard shortcuts |
||
| 18101 | New Feature | Add PDA UI metadata to trace file. The TraceFile also stores UI settings. These include: |
||
| 18041 | New Feature | Virtual SIgnal - Range filter. | ||
| 18034 | New Feature | Import RAYGUIDE Overlay. | ||
| 18016 | New Feature | More Quadrature Signals. (Quadrature0Distance, Quadrature0Speed, Quadrature0TickCount). - Quadrature0Distance, Quadrature1Distance (in µm) |
||
| 18004 | New Feature | Absolute time axes. | ||
| 17966 | New Feature | Virtual Signal - low pass filter. | ||
| 17960 | New Feature | Add live view of trace buffer data without recording. | ||
| 17946 | New Feature | Show warning why a virtual signal is not available. If a signal cannot be used, there are two reasons: |
||
| 17875 | New Feature | Multisegement streaming. | ||
| 17874 | New Feature | Open file: Batch selection. | ||
| 17829 | New Feature | Custom trigger events. | ||
| 16883 | New Feature | Before an acquisition is started, the PDA check if scan head monitoring is active and displays a warning if necessary. | ||
| 15567 | New Feature | Option to switch display of digital data from Dezimal to Hex display. All signals except position signals can be displayed as hexadecimal values. |
||
| 15259 | New Feature | Add option to have an XY plot for position signals in scanner domain. | ||
| 1.4.4 | 02.07.2026 | 18214 | BUG | Can't activate trail license. |
| 1.4.3 | 19.03.2026 | 17938 | BUG | Inverse field correction doesn't support correction files with defocus. |
| 17781 | BUG | Can't connect to card or load trace file without a correction file. | ||
| 17782 | Change Request | Improved the handling of existings XY measure points. | ||
| 1.4.2 | 21.01.2026 | 17674 | BUG | Can't disable RxFieldSignal in configuration dialog. |
| 14935 | Change Request | rework context menu design. | ||
| 17734 | New Feature | Add Quadrature Trace Signals Quadrature0(I/A/B) and Quadrature1(I/A/B). | ||
| 1.4.1 | 02.12.2025 | 17576 | BUG | Can't use PDA on demo mode (no license). |
| 17574 | BUG | No XY plot while using a pretrigger time. | ||
| 17577 | New Feature | Simulateted X/Y position can be used as input signal for other virtual signals. | ||
| 17517 | New Feature | Recent document in "File" menu. | ||
| 15782 | New Feature | New virtual signals: acceleration and jerk. | ||
| 1.4.0 | 03.11.2025 | 17504 | BUG | Trace data export: Time range of A + B cursor are ignored on export. |
| 17424 | BUG | XY plot signal value coloring not working. | ||
| 17354 | BUG | XY plot shows phantom lines. | ||
| 17275 | BUG | A/B Cursor not visible when "auto resizing" is deactiveted. | ||
| 17425 | New Feature | Virtual signal can be used as an input signal for another virtual signal. | ||
| 17245 | New Feature | Trace data export: User can change the behaviour of time value (start at 0), compress export, normalize time to 10µs. | ||
| 17234 | New Feature | Add virtual signal to loaded trace. | ||
| 1.3.0 | 17.07.2025 | 17096 | BUG | For some correction files the inverse XY positions were always set to 0/0. |
| 17098 | New Feature | Add setting to XY context menu to show crosshair cursor on XY plot. | ||
| 17097 | New Feature | A/B cursors can be set via the context menu of the XY plots. | ||
| 17095 | New Feature | New field signals "Simulated Field XY" uses PT6 method to simulate measured signals. | ||
| 16853 | New Feature | New feature to change the size and color for T-Cursor in the Preferences dialog. | ||
| 16416 | New Feature | New virtual sIgnal "position offset". | ||
| 1.2.0 | 14.03.2025 | 16838 | BUG | No license left after connection problems. |
| 16836 | BUG | T-cursor shows wrong positon on XY-chart. | ||
| 16835 | BUG | Correction file contained in the trace file is now used by the PDA. | ||
| 16587 | BUG | Can't load trace file saved with version lower than 1.1.1. | ||
| 16597 | Change Request | Streaming API: Make timestamp optional to include time 0 in frame. | ||
| 16575 | Change Request | Change API Pre-Trigger config from microseconds to milliseconds. | ||
| 15832 | New Feature | New virtual signals: Sum and mean value. | ||
| 15804 | New Feature | Option to mask IO ports for tracing a single bit. | ||
| 1.1.1 | 14.11.2024 | 16456 | BUG | Fix SPICE3 updated API - Axis index out-of-range error. |
| 1.1.0 | 21.10.2024 | 16402 | New Feature | Add streaming feature to API. |