Raylase_Logo_Neuer-Claim

Process Data Analyzer - Change log

Version Released # Type Description
2.0.0 22.09.2026 18256 Change Request Auto fit after acqusition.
17384 Change Request Signal timing is stored per card.

The unit of time has been changed to microseconds.

15760 Change Request Change the configuration to be card related.

The new feature saves the configuration for each card. Trace files save the configuration on a special card with ConnectionID = “TRACE_FILE_DUMMY_DEVICE”.

18444 New Feature Separate UI from data acquisition. By default it runs as a client of the RAYLASE.PDA.Service and gets its data over the API.
18397 New Feature Displays the unsupported signals, depending on the firmware version.
18285 New Feature New Timeplot Zooming mode left aligned. Use SHIFT + Scoll to activate that mode.
18277 New Feature With Mulitsegment trigger the trace file can split to an individual file per segment.
18257 New Feature Enhancement of the “PDA Support File”.

All open trace files and loaded overlays are now added to the support file.

- TraceFile subfolder for open trace files
- Overlay subfolder for used overlays.

18213 New Feature new virtual signals (ZeroPhasePT2, MovingAverage, Count, InRange).

- ZeroPhasePT2: Zero-phase second-order digital filter.
- MovingAverage: Moving average of signal. Use k - data points.
- Count: Counts the number of occurrences of the selected signal (input is empty). It is also possible to count only a specific value.
- InRange: If signal value is in range the virtual signal is 1 outside is 0.

18129 New Feature New keyboard shortcuts for timeplot (Pos1, End, PageUp and PageDown).

new keyboard shortcuts
- POS1 go to first segment point
- END go to last segment point
- PAGE DOWN scrolls to the left
- PAGE UP scrolls to the right.

18101 New Feature Add PDA UI metadata to trace file.

The TraceFile also stores UI settings. These include:
- Position of the A and B cursors
- Chart settings (position and zoom factor).

18041 New Feature Virtual SIgnal - Range filter.
18034 New Feature Import RAYGUIDE Overlay.
18016 New Feature More Quadrature Signals. (Quadrature0Distance, Quadrature0Speed, Quadrature0TickCount).

- Quadrature0Distance, Quadrature1Distance (in µm)
- Quadrature0Speed, Quadrature1Speed (in m/s)
- Quadrature0TickCount, Quadrature1TickCount (number of encoder ticks).

18004 New Feature Absolute time axes.
17966 New Feature Virtual Signal - low pass filter.
17960 New Feature Add live view of trace buffer data without recording.
17946 New Feature Show warning why a virtual signal is not available.

If a signal cannot be used, there are two reasons:
1. The signal is not provided or supported by the hardware (Red)
2. The user has not selected the signal (Orange). The PDA will resolve this issue automatically.

17875 New Feature Multisegement streaming.
17874 New Feature Open file: Batch selection.
17829 New Feature Custom trigger events.
16883 New Feature Before an acquisition is started, the PDA check if scan head monitoring is active and displays a warning if necessary.
15567 New Feature Option to switch display of digital data from Dezimal to Hex display.

All signals except position signals can be displayed as hexadecimal values.

15259 New Feature Add option to have an XY plot for position signals in scanner domain.
1.4.4 02.07.2026 18214 BUG Can't activate trail license.
1.4.3 19.03.2026 17938 BUG Inverse field correction doesn't support correction files with defocus.
17781 BUG Can't connect to card or load trace file without a correction file.
17782 Change Request Improved the handling of existings XY measure points.
1.4.2 21.01.2026 17674 BUG Can't disable RxFieldSignal in configuration dialog.
14935 Change Request rework context menu design.
17734 New Feature Add Quadrature Trace Signals Quadrature0(I/A/B) and Quadrature1(I/A/B).
1.4.1 02.12.2025 17576 BUG Can't use PDA on demo mode (no license).
17574 BUG No XY plot while using a pretrigger time.
17577 New Feature Simulateted X/Y position can be used as input signal for other virtual signals.
17517 New Feature Recent document in "File" menu.
15782 New Feature New virtual signals: acceleration and jerk.
1.4.0 03.11.2025 17504 BUG Trace data export: Time range of A + B cursor are ignored on export.
17424 BUG XY plot signal value coloring not working.
17354 BUG XY plot shows phantom lines.
17275 BUG A/B Cursor not visible when "auto resizing" is deactiveted.
17425 New Feature Virtual signal can be used as an input signal for another virtual signal.
17245 New Feature Trace data export: User can change the behaviour of time value (start at 0), compress export, normalize time to 10µs.
17234 New Feature Add virtual signal to loaded trace.
1.3.0 17.07.2025 17096 BUG For some correction files the inverse XY positions were always set to 0/0.
17098 New Feature Add setting to XY context menu to show crosshair cursor on XY plot.
17097 New Feature A/B cursors can be set via the context menu of the XY plots.
17095 New Feature New field signals "Simulated Field XY" uses PT6 method to simulate measured signals.
16853 New Feature New feature to change the size and color for T-Cursor in the Preferences dialog.
16416 New Feature New virtual sIgnal "position offset".
1.2.0 14.03.2025 16838 BUG No license left after connection problems.
16836 BUG T-cursor shows wrong positon on XY-chart.
16835 BUG Correction file contained in the trace file is now used by the PDA.
16587 BUG Can't load trace file saved with version lower than 1.1.1.
16597 Change Request Streaming API: Make timestamp optional to include time 0 in frame.
16575 Change Request Change API Pre-Trigger config from microseconds to milliseconds.
15832 New Feature New virtual signals: Sum and mean value.
15804 New Feature Option to mask IO ports for tracing a single bit.
1.1.1 14.11.2024 16456 BUG Fix SPICE3 updated API - Axis index out-of-range error.
1.1.0 21.10.2024 16402 New Feature Add streaming feature to API.