RAYGUIDE Vision Solution - Change log

Version Released # Type Description
2.18.0 21/02/2025 16736 BUG Click & Teach: Camera calibration: Changing the "Sensor axis offset" resets the focus level to 0.
16798 Change Request Click & Teach: Improve equalization.

Equalization is improved by adding a new, alternative calibration method using 16 tiles instead of only 8. The equalization can be done now using cubic interpolation between tiles instead of quadratic interpolation, which leads to much better results.

16799 New Feature Click & Teach: Improved camera calibration usability.

New mode for finding calibration crosses automatically by means of image processing. Moving calibration lines manually is no longer necessary. Complete equalization calibration can be done with just one button click.

2.11.0 08/10/2024 16266 Change Request Click & Teach: Enhanced equalization.

Equalization quality is significantly enhanced by modifying the equaliziation algorithm. The user can choose between quadratic or even better cubic interpolation now.

2.10.0 24/09/2024 16283 BUG Click & Teach: Switching between jobs can last a long time if the background has been tiled.
2.8.0 14/08/2024 16177 BUG Click & Teach: When using a JAI camera and the live view is switched on, RAYGUIDE may crash while picking or tiling.
16195 BUG Click & Teach: The calibration job is created at z-level 0 although another z-level is defined in the camera settings dialog.
16196 BUG Click & Teach: Wave length/rectification calibration: The camera image is not displayed if background opacity is set to 0.
2.7.0 22/07/2024 16118 BUG Click & Teach: The equalization calibration job is created with wrong coordinates if the camera is not set to full resolution.
16116 BUG Click & Teach: The camera's center calibration can not be set if the camera's resolution is smaller than its physical size.
2.4.1 05/06/2024 15999 BUG Click & Teach: Equalization calibration fails if the camera's image size is reduced.
2.2.0 30/04/2024 15738 BUG Click & Teach: Gain sometimes not set on DALSA camera.
15863 BUG Click & Teach: When loading a camera calibration, the currently selected tile position entries are not updated.
2.0.0 04/04/2024 15691 BUG Click & Teach: With Dalsa cameras the feature "combine four pixels into one" does not work reliably.
1.52.0 26/01/2024 15621 BUG Click & Teach: Rayguide crashes when tiling, if the workspace configuration has no deflection unit assigned to it.
15592 BUG Click & Teach: A z-offset in the correction file is not handled correctly when creating calibration jobs.
15591 BUG Click & Teach: When using two cameras, connecting and disconnecting the cameras can cause problems.
15615 New Feature Click & Teach: Option for disabling pointer during image acquisition.
15433 New Feature Click & Teach: Option for clearing background after execution.
1.51.0 09/01/2024 15553 BUG Click & Teach: Equalization is inaccurate in case there is a scan head orientation configured (i. e. orientation not equal 0°).
15550 BUG Click & Teach: Equalization is not working any longer on 2-axes systems and on 3-axes systems without changing the focus level.
1.50.0 21/12/2023 15527 BUG Click & Teach: In case of scan fields with z-range, the z-level in the camera calibration dialog cannot be set reliably.
15525 BUG Click & Teach: In case a workspace is smaller than the scan field, the equalization calibration job is created too big.
1.49.0 04/12/2023 15362 New Feature Click & Teach: Improved offset calibration.

New camera offset calibration for each of the workspace's corners. The used offset is interpolated between the already available center offset and the new corners' offsets. The new offset calibration is integrated into the equalization calibration procedure.

1.46.0 13/10/2023 15202 BUG Click & Teach: A new camera could not be added to the devices without the Click&Teach panel being loaded and visible.
1.45.0 30/08/2023 15148 BUG Click & Teach: Calibration jobs are created at the wrong z position if z is not 0.
15034 Change Request Click & Teach: A field transformation cannot be used while calibrating the camera.

The field transformation can be used now to improve the correction file if necessary. When creating the background image for the workspace, only the rotational component of the field transformation is compensated; gain and offset are ignored.

15010 New Feature Click & Teach: New automation object - Acquire and save image.
15012 New Feature Click & Teach: New automation object - Set illumination.
15126 New Feature Click & Teach: Support camera calibration for FOCUSSHIFTER in different focus positions.
1.43.2 07/06/2023 14938 BUG Click & Teach: The guide lines for equalization calibration do not show up.
1.43.0 30/05/2023 14750 Change Request Click & Teach: remove autocalibration for calibration of real cameras.

Auto calibration is still available for the camera emulator but not for real cameras any longer.

14752 New Feature Click & Teach: New device: Illumination controller.

Gardasoft illumination controllers are supported.

14751 New Feature Click & Teach: Enhancement of camera calibration to correct distortions.
14753 New Feature Click & Teach: New panel: Illumination controll.
14914 New Feature Click & Teach: Zoom option for live image.
14913 New Feature Click & Teach: Live Image full screen mode.
14754 New Feature Click & Teach: Option for displaying gray value gradient.
1.39.0 26/01/2023 14555 BUG Click & Teach: In case of 3D scanners the camera calibration can be lost.
14592 BUG Click & Teach: The alignment line in the live view cannot be activated until the camera is calibrated.

The alignment line can be activated now as soon as the live view is available.

1.38.0 14/12/2022 14527 BUG Click & Teach: Picking mode "Selection rectangle" interrupts camera calibration when the mouse key is released.
1.35.0 05/10/2022 14333 BUG Click & Teach: Sometimes the live view cannot be started without reconnecting the camera.
1.33.0 06/09/2022 14273 New Feature Click & Teach: Option for contrast enhancement in live view and tiled images.

New sliders for brightness and contrast in Click&Teach panel.

1.32.1 22/08/2022 14245 BUG Click & Teach: Calibration job marked at wrong z-position.
1.30.0 21/07/2022 14175 BUG Click & Teach: Preview causes an exception when a cycle is over.
14144 BUG Click & Teach: Calibration job may be too large for the scan field.

The calibration job's size will be smaller if it doesn't fit into the scan field or workspace. Minimal size is 2 cm x 2 cm.

1.29.0 12/07/2022 13933 New Feature Click & Teach: Add virtual alignment grid to live image window.

There is a movable, horizontal alignment line in the live view now.

1.28.0 07/07/2022 14139 BUG Click & Teach: The wave length correction does not take scan field rotations into account.

The scan field's rotation does not matter any longer when calibrating the wave length correction.

14138 BUG Click & Teach: When using a JAI camera the background image is not cleared reliably.
1.27.0 13/06/2022 14078 BUG Click & Teach: JAI camera needs an additional disconnect and connect after starting RAYGUIDE.
1.24.0 03/05/2022 13980 BUG Click & Teach: Camera calibrating does not work correctly when the scan head has a rotation in its field transformation.

Click&Teach: Mounting the camera with the correct rotation angle failed when the scan head contained a rotation in the field transformation while creating the calibration job. Only the scan head's orientation (90°, 180°, 270°) is taken into account now when creating the calibration job.

1.21.0 23/02/2022 13788 BUG Click & Teach: Tiling exceeds image size limits when used with large scan fields.
1.19.0 03/02/2022 13704 New Feature Click & Teach 2.5D.

The Click & Teach add-on can be used in 2.5D environments now and allows to set the focus along the z-axis.