Scanfield Manager - Change log

Version Released # Type Description
2.1.1 20/03/2025 16871 BUG Fix incorrect assignment of columns/row counts for a scanner rotated by 90/270 degrees in result visualization.
2.1.0 12/03/2025 16822 BUG Fix Single Field vector plot orientation for a rotated scanner.
16690 BUG Preview button is blocked, while preview is active.
16689 BUG Objects inside container are processed sequentially in multi field setup.
16688 BUG RemoteInterface: Arm command did not "arm" in all cases.
16687 BUG Rare possibility of dead lock during execution.
16086 BUG Pitch of the features for all calibrations has changed due to the addition of a gain error.
16085 BUG Pitch of the multifield features has changed due to the sum of the rotation error and the offset error.
16667 Change Request Single Field analysis: Implement visualization of data in different layers of a 3D correction file.
16662 Change Request Show a warning if an entire column/row is not detected during the analysis.
16641 Change Request Single Field and Z Calibration analysis: display amount and percentage of features/group detected.
16661 Change Request Multi Field analysis: Allows visualization of data before and after scanner alignment corrections.
16660 Change Request Improve vector plot navigation: save viewport on plate change and adds reset view button.
16659 Change Request Add legend to the magnitude table.
16658 Change Request Highlight in different colors magnitude table cells with interpolated data, undetected features or missing values.
16657 Change Request Update Vector Plot graphics and improve speed of plotting.
16656 Change Request Improve speed of surface plot data computation.
16655 Change Request Reorganize UI for calibration settings and introduce "@Object boundary" and "@Object interior" parameters.
16654 Change Request Add visualization of plate placement to marking view.
16653 Change Request Multi Field: Increase space between QR code/fiducials and other features.
16647 Change Request Improve progress bar estimated time during marking.
16646 Change Request Save the last selected workspace used in the user settings.
16644 Change Request Relocate "Load/Save calibration" from Device Calibration settings to Image Provider settings.
16642 Change Request Single Field and Z Calibration analysis: calibration result is a "failure" if less than 90% features/groups are detected.
16639 Change Request Show a pop up warning when applying Z calibration if a bias is configured.
16663 New Feature Improve image analysis process to be faster and more memory-efficient.
16648 New Feature Show calibration setting in the history.
16666 New Feature Single Field: Implement update of 3D correction files, interpolating data from a single-layer calibration.
16665 New Feature Multi Field: Add support for calibration with plates smaller than the scanner field size.
16643 New Feature Introduce new parameter "Maximum gain error" for all calibrations.
2.0.4 31/01/2024 15660 Change Request Added warning when trying to save a read-only database or a database located in a read-only directory.
15663 Change Request Improved the plate placement and pattern design for MultiFieldXY calibrations.
15662 Change Request Improved computation of alignment errors in analysis of MultiFieldXY calibrations.
15661 New Feature Added feature/group count (both detected and expected) to analysis info for all available calibrations.
15659 New Feature Add progress bar to marking view.
2.0.3 22/11/2023 15434 Change Request Changed design of MultiFieldXY pattern. All calibration features are now positioned on a common grid shared by all scanners.
15436 Change Request Improved computation of error tables that are used to update the correction files at the end of a calibration.
15435 Change Request Improved computation of alignment errors in analysis of MultiFieldXY calibrations.
15437 New Feature Added option to create a new database when first launching the application as well as in the setup dialog.
2.0.2 18/10/2023 15320 BUG The "Configure devices…" dialog has been corrected so that changes are possible again.
2.0.1 17/10/2023 15289 Change Request Enhanced error report package to include all SP-ICE-3 logs including archived logs.
15301 Change Request Now supports SP-ICE-3 firmware version 3.x.
15295 Change Request The pilot laser will now automatically turn on when the preview is started.
15300 New Feature Laser-specific "On/Off" delays can now be configurabled in the "Laser Configuration Dialog".
15297 New Feature Added link to the change log and credits to "About" dialog and installer.
15296 New Feature Export of error tables as measurement tables in MPE-compatible format.
15293 New Feature Added exception for all calibrations when the number of detected features is much lower than expected.
15298 New Feature Added menu entry "Activate license...".
2.0.0 03/08/2023 15074 BUG Cancel preview failed sporadically and arm laser starts to mark the pattern box.
15073 BUG HeadBias is reset to the last configured value after a pattern is marked.
15075 BUG A warning is displayed if no device calibration exists for an imported image.
15078 New Feature Focus map of Z calibration is now computed in units of "x Rayleigh" (previously, in "lines").

The unit "x Rayleigh" stands for "multiples of Rayleigh length", and offers a more tangible interpretation by how much the scanner is in or out of focus.

15082 New Feature Subfield definition replaced by workspace definition.

The "sub field", which previously was available only to a few calibrations, has been succeeded by the "workspace". The workspace includes size, offset, scanners and their arrangements. With the workspace, the concept of sub fields is now available to all calibrations.

15079 New Feature Added feature "calibration history".

All past correction files can be reviewed with details such as date, parent, reason of change (i.e. type of calibration).
Any correction file from this list can be reactivated, i.e. restored and automatically uploaded to the corresponding scan controller.

15077 New Feature A change of the device configuration by a second SFM instance no longer requires an application restart.

In case, the device configuration is changed outside the active application (for example, by another SFM instance), then a restart is no longer necessary. Instead, the application will detect the change (via its database), and automatically apply the new configuration.

15084 New Feature New multi field XY calibration behavior.

The new implementation determines the number of plates necessary based on the plate size, the number of scanners to be calibrated and their arrangement, and the configured tolerances.
In a best-case situation, all scanners may be calibrated with just one plate.

15080 New Feature Scanlab’s scan controllers RTC5 and RTC6 are now supported.
15076 New Feature Added license info and RAYLASE logo to "About" dialog.
1.0.3 20/01/2023 14581 BUG After a successful calibration the involved controller cards still use the old version of their correction files for marking.

The bug only occurs when a card cannot be accessed while its correction file is modified by a calibration. In this case, the correction file is only modified on the file system but doesn't change on the card. This fix ensures that the modified correction file is uploaded to the card before marking again within the Scanfield Manager. If you use another application to mark after a calibration this issue might still occur.

14513 BUG Sometimes the crosses for ZCalibration are moved to a wrong position.
14582 New Feature Option to change the Z-position at which a calibration pattern will be marked.
1.0.2 18/11/2022 14464 BUG Analyzing a SingleFieldXY calibration pattern that was marked with a field rotation of 180° causes an error.
14463 New Feature Redesign correction history to be in the style of a version control.
1.0.1 14/11/2022 14441 BUG Single field calibration: Non-zero subfield offsets lead to malformed correction file.
14444 New Feature Option to import and export the device and workspace configuration from a RAYGUIDE installation or another SFM installation.