Click or drag to resize

ExportRequest(String, Time, Time, Card, SignalWithUnit, NullableBoolean, NullableBoolean, NullableBoolean, NullableBoolean, NullableBoolean, NullableBoolean) Constructor

Exports acquired trace data.

Namespace: RAYLASE.PDA.API
Assembly: RAYLASE.PDA.API.Protos (in RAYLASE.PDA.API.Protos.dll) Version: 2.0.0.10
Syntax
C#
public ExportRequest(
	string exportPath,
	Time? from = null,
	Time? to = null,
	Card? card = null,
	SignalWithUnit[]? signalWithUnit = null,
	bool? useDecimalPoint = null,
	bool? writeHeaders = null,
	bool? writeTimestamps = null,
	bool? writeNormalizedTime = null,
	bool? writeTime10Us = null,
	bool? writeCompressed = null
)

Parameters

exportPath  String
Path to save exported signals to (for PC running the service).
from  Time  (Optional)
Start of export in µs; defaults to first timestamp (0 µs).
to  Time  (Optional)
End of export in µs, defaults to last timestamp.
card  Card  (Optional)
If set exports acquired trace data for set card, otherwise for all currently connected devices.
signalWithUnit  SignalWithUnit  (Optional)
Signal( s) with unit( s) to export, defaults to all signals with default/last used units.
useDecimalPoint  NullableBoolean  (Optional)
True: Use point "." as decimal separator; False: Use comma ",". Defaults to false (comma ",").
writeHeaders  NullableBoolean  (Optional)
Write the export file headers. Defaults to true.
writeTimestamps  NullableBoolean  (Optional)
Write an additional timestamp column to the export file. Defaults to false.
writeNormalizedTime  NullableBoolean  (Optional)
Write time values starting with 0 µs. Defaults to false.
writeTime10Us  NullableBoolean  (Optional)
Round exported time values to 10 µs mapping. Defaults to false.
writeCompressed  NullableBoolean  (Optional)
Write only changed data rows. Defaults to false.
See Also