4.1 XY2-100 Adapter

Connector Locations

XY2_Overview.svg not found.

Connection to SP-ICE-3 Card

The XY2-100 Adapter is delivered with two ribbon cables, which should be used to connect the adapter to the card as follows:

XY2-100 Adapter

SP-ICE-3 Card

Notes

J3

X403

Caution note  Caution

Make sure that the SP-ICE-3 Card is not powered when connecting to X403, otherwise the FPGA will be damaged.

J4

X1000

In order to control laser power via the analog output of J2 you must connect J4 to X1000 Analog on the SP-ICE-3 Card.

However, if you wish to use a separate laser interface adapter that requires the connection to X1000 itself (for example, the TruPulse Nano / SPI Laser-Adapter), you should disconnect and remove the cable from J4. In this case the analog output of J2 will not be available.