4.3.4.3 Pre-Configuration IPG Interface YLP-HP-B |
The output Alarm signal (J3 pin 26) to the SP-ICE-3 Card will be activated whenever any of a pre-configured set of patterns of active alarm inputs is recognised.
On the SP-ICE-3 Card the Alarm signal will cause the currently running job to be aborted.
The main power supply of the YLP-HP-B laser can be switched on using the VIO_out 5V output on pin 17.
Depending on the DIP-switch setting, Pin 17 output can either be controlled by PortD.4, or always enabled.
Note that the laser requires a signal on pin 13 (Reserved Output_2) to reset an alarm state.
Pin 13 can be controlled by writing to PortD.19.
The Alarm1..Alarm4 input signals from the laser are used to evaluate the state of the laser, as shown in the YLP-HP-B Alarm Table, below:
Column(s) | Description |
---|---|
Alarm1..Alarm4 | The states of the alarm input signals from the laser. |
Priority and Name | As shown in the IPG YLP-HP-B manual. |
SP-ICE-3 Job | Whether the job running on the SP-ICE-3 card will be aborted in that alarm state. In other words, whether the output Alarm signal will be activated. |
LED columns | The state of the Yellow Alarm (D10) and Red System Alarm (D11) LEDs on the bracket, and the Green LED D1 on the adapter's PCB. Note that the Yellow Alarm LED (D10) will be overridden to blink whenever the shutter J2 on the IPG-comp interface is open. |
Alarm4 |
Alarm3 |
Alarm2 |
Alarm1 | Priority | Name | SP-ICE-3 Job |
Yellow Alarm |
Red System Alarm |
Green |
---|---|---|---|---|---|---|---|---|---|
LOW | LOW | LOW | LOW | 4 | Temperature Alarm | Abort | ON | ON | OFF |
LOW | LOW | LOW | HIGH | 3 | Back Reflection Alarm | Abort | ON | ON | OFF |
LOW | LOW | HIGH | LOW | 12 | Laser Waiting For Emission | Run | OFF | OFF | ON |
LOW | LOW | HIGH | HIGH | 2 | System Alarm | Abort | ON | ON | OFF |
LOW | HIGH | LOW | LOW | 5 | Fiber Alarm | Abort | ON | ON | OFF |
LOW | HIGH | LOW | HIGH | 9 | Safety Interlock Open | Abort | ON | OFF | OFF |
LOW | HIGH | HIGH | LOW | 11 | Laser Not Ready For Emission | Run | OFF | OFF | OFF |
LOW | HIGH | HIGH | HIGH | 0 | Optical Link Alarm | Abort | ON | ON | OFF |
HIGH | LOW | LOW | LOW | 1 | Critical Alarm | Abort | ON | ON | OFF |
HIGH | LOW | LOW | HIGH | 7 | Hot stop | Abort | ON | ON | OFF |
HIGH | LOW | HIGH | LOW | 10 | Main Power Supply OFF | Run | OFF | OFF | OFF |
HIGH | LOW | HIGH | HIGH | 13 | Emission ON | Run | OFF | OFF | ON |
HIGH | HIGH | LOW | LOW | 8 | Safety Circuit Blocked | Abort | ON | OFF | OFF |
HIGH | HIGH | LOW | HIGH | 6 | Interface Controller 24V Alarm | Abort | ON | ON | OFF |
HIGH | HIGH | HIGH | LOW | n.a. | unused | Abort | ON | OFF | OFF |
HIGH | HIGH | HIGH | HIGH | n.a. | unused | Abort | ON | OFF | OFF |