Click or drag to resize

4.3.4.5 Legacy DIP-Switch and Jumper Configuration (deprecated)

The IPG-compatible Adapter hardware can be configured for any one of several similar laser types by means of jumpers W1..W6 and DIP-switch S1.

Note  Note

This page only applies to adapter hardware version R2 001 V2 or R3 001 V0 and is otherwise deprecated.

Jumpers W1..W6

The jumpers are used to select input and output functions of the configurable pins on Connector J1.

FLA_Jumper.svg
J1 Pin Function Mapping

Jumper

J1 Pin

Jumper pins 1,2
(upper pair)

Jumper pins 2,3
(lower pair)

W1

15

Sync_Alarm (Input)

N.C.

W2

11

Alarm3 (Input)

N.C.

W3

24

Back_Alarm (Input)

Reserved_Output_1 (Output)

W4

12

Alarm4 (Input)

N.C.

W5

25

Power_Monitor (Input)

N.C.

W6

13

Reserved_Output_2 (Output)

N.C.

DIP-switch S1

Various combinations of S1.1-4 are used to select:

  • the specific laser type;

  • the polarity of the input alarm signals;

  • whether the 5V 500mA output on J1 pin 17 is enabled;

  • either of two major adapter modes:

    4.3.5.1 Universal Mode (deprecated).

    The output Alarm signal (J3 pin 26) to the SP-ICE-3 Card will be activated whenever at least one of the input alarms is active.

    4.3.5.2 Super Mode (deprecated).

    The output Alarm signal (J3 pin 26) to the SP-ICE-3 Card will be activated whenever any of the set of specified patterns of active alarm inputs is recognised.

    Note  Note

    Super Mode (and YLP-HP-B Mode) are only available on adapter hardware version R2 001 V2 or later.

FLA_DIP-switch.svg
Configuration Mapping

Laser

Jumpers

S1

Alarm1
Pin 16

Alarm2
Pin 21

Alarm3
Pin 11

Alarm4
Pin 12

Back_Alarm
Pin 24

Sync_Alarm
Pin 15

VIO_out 5V
Pin 17

IPG Interface B, C, D, E

Without external pointer supply.

Also valid for:

  • Max Photonics

  • SpectraPhysics VGEN Series

  • Raycus

  • Nufern Laser

  • JPT Laser[Note 1]

FLA_Jumper_small_IPG.svg not found.
FLA_DIP-switch-off-off-off-off.svg not found.

low normal

high normal

low normal

disconnected

disconnected

disconnected

off

IPG Interface B, C, D, E

With pointer supply.

FLA_Jumper_small_IPG.svg not found.
FLA_DIP-switch-off-off-off-on.svg not found.

low normal

high normal

low normal

disconnected

disconnected

disconnected

on

Quantel

No pointer option

FLA_Jumper_small_Quantel_Manlight.svg not found.
FLA_DIP-switch-off-off-on-off.svg not found.

low normal

high normal

disconnected

disconnected

low normal

high normal

off

Quantel

With pointer supply.

FLA_Jumper_small_Quantel_Manlight.svg not found.
FLA_DIP-switch-off-off-on-on.svg not found.

low normal

high normal

disconnected

disconnected

low normal

high normal

on

Universal Mode

See: 4.3.5.1 Universal Mode (deprecated)

FLA_Jumper_small_custom.svg not found.
FLA_DIP-switch-on-on-on-on.svg not found.

custom

custom

custom

custom

custom

custom

register selectable

IPG Interface YLP-HP-B

This Mode is only supported with hardware version R2 001 V2 or newer.

FLA_Jumper_small_IPG-YLP-HP-B.svg not found.
FLA_DIP-switch-on-off-off-off.svg

connected

connected

connected

connected

disconnected

disconnected

Controlled by PortD.4

IPG Interface YLP-HP-B

This Mode is only supported with hardware version R2 001 V2 or newer.

FLA_Jumper_small_IPG-YLP-HP-B.svg not found.
FLA_DIP-switch-on-off-off-on.svg not found.

connected

connected

connected

connected

disconnected

disconnected

on

Super Mode

This Mode is only supported with hardware version R2 001 V2 or newer.

See: 4.3.5.2 Super Mode (deprecated)

FLA_Jumper_small_custom.svg not found.
FLA_DIP-switch-on-on-on-off.svg not found.

custom

custom

custom

custom

custom

custom

register selectable

Notes
  1. Pulse width adjustment is not yet supported.